Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 358, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509532

RESUMO

OBJECTIVE: This study aimed to evaluate enamel surface integrity and time consumed during residual cement removal after bracket debonding using different adhesive removal burs with and without a dental loupe. MATERIAL AND METHODS: Sixty human-extracted premolars were collected, cleaned, mounted, and prepared for orthodontic bracket bonding. Teeth were randomly divided into three main groups (n = 20) based on the adhesive removal method: tungsten carbide system (TC), sof-lex discs system (SD), and diamond system (DB) groups. Then, each group was subdivided into two subgroups (naked eye and magnifying loupe subgroups). The brackets were bonded and then debonded after 24 h, and the Adhesive Remnant Index (ARI) was assessed. The adhesive remnants were removed by different systems, and the final polishing was performed by Silicone OneGloss. The enamel surface roughness was evaluated before bracketing (T0), after residual cement removal (T1), and finally after polishing (T2) using surface Mitutoyo SJ-210 profilometry and Scanning Electron Microscopy (SEM) to determine the Enamel Damage Index (EDI) score. The time consumed for adhesive removal was recorded in seconds. RESULTS: The Kruskal Wallis test showed a statistically significant difference in roughness values at T1 compared to T2 between subgroups (p < 0.001). When comparing EDI at T1 and T2, the Kruskal-Wallis H-test showed statistically significant differences in all subgroups. The pairwise comparisons revealed that EDI scores showed a statistically significant difference at T1 and T2 between DB vs. TC and SD (p = 0.015) but not between TC vs. SD (p = 1.000), indicating the highest roughness value observed in the DB group. The time for cement removal was significantly shorter in the magnifying loupe group than in the naked eye group and was shortest with the TC group, whereas the time was the longest with the DB group (p < 0.05). CONCLUSION: All three systems were clinically satisfactory for residual orthodontic adhesive removal. However, TC system produced the lowest enamel roughness, while the DB system created the greatest. The polishing step created smoother surfaces regardless of the systems used for resin removal.


Assuntos
Cimentos Dentários , Braquetes Ortodônticos , Compostos de Tungstênio , Humanos , Dente Pré-Molar , Descolagem Dentária , Esmalte Dentário , Cimentos de Ionômeros de Vidro , Braquetes Ortodônticos/efeitos adversos , Propriedades de Superfície
2.
BMC Oral Health ; 23(1): 478, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443027

RESUMO

BACKGROUND: The main goal of orthodontic debonding is to restore the enamel surface as closely as possible to its pretreatment condition without iatrogenic damage. This study aimed to compare the effects of different adhesive removal burs; zirconia burs, tungsten carbide burs, and white stone burs on enamel surface roughness. MATERIALS AND METHODS: Total sample of 72 extracted premolars was randomly divided into three equal groups (n = 24) depending on the method of adhesive removal: zirconia burs (ZB); tungsten carbide burs (TC); and white stones (WS). The metal brackets were bonded using Transbond XT orthodontic adhesive (3 M Unitek, Monrovia, CA, USA) and debonded after 24 h using a debonding plier, then the ARI was assessed. The adhesive remnants were removed using the different burs and Final polishing was performed using Sof-lex discs and spirals. Thirteen samples from each group were evaluated using a Mitutoyo SJ-210 profilometer to determine average surface roughness (Ra) and three samples from each group were examined under Scanning Electron Microscopy (SEM) to determine EDI score. The evaluations were performed at three time points; before bonding (T0), after adhesive removal (T1) and after polishing (T2) and the time consumed for adhesive removal by burs was recorded in seconds. The data were analyzed statistically by ANOVA, Tukey's test and Kruskal-Wallis H-test. RESULTS: Kruskal-Wallis H-test showed no statistically significant difference of ARI in all studied groups (p = 0.845) and two-way mixed ANOVA revealed that all burs significantly increased surface roughness at T1 compared to T0 (p < 0.001) in all groups with the lowest Ra values were observed in the ZB group, followed by the TC group, and WS group. The fastest procedure was performed with WS, followed by ZB, then TC bur (p < 0.001). After polishing (T2), Ra values showed no significant difference in ZB group (P = 0.428) and TC group (P = 1.000) as compared to T0, while it was significant in WS group (p < 0.001). CONCLUSION: zirconia bur was comparable to tungsten carbide bur and can be considered as alternative to white stone which caused severe enamel damage. The polishing step created smoother surface regardless of the bur used for resin removal.


Assuntos
Cimentos Dentários , Braquetes Ortodônticos , Humanos , Descolagem Dentária/métodos , Esmalte Dentário , Propriedades de Superfície
3.
Clin Oral Investig ; 27(9): 5011-5020, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37358688

RESUMO

OBJECTIVE: This study evaluated the dimensional and positional osseous temporomandibular joint features in normodivergent facial patterns with and without temporomandibular disorders. METHODS: A total of 165 adult patients were divided into two groups: group 1 (n = 79 patients; 158 joints): temporomandibular disorders patients and group 2 (n = 86 patients; 172 joints): non-temporomandibular disorders patients. Three-dimensional positional and dimensional temporomandibular joint characteristics, including glenoid fossa, mandibular condyles, and joint spaces, were assessed by cone beam computed tomography. RESULTS: The glenoid fossa positions in the three orthogonal planes and height showed statistical significance between the two studied groups. The temporomandibular disorders patients showed higher horizontal and vertical condyle inclinations while anteroposterior inclination was less, and the condyle was positioned more superior, anterior, and lateral in the glenoid fossa. The condyle width and length showed no significance between the two groups, while condyle height was smaller in temporomandibular disorders patients. Anterior and medial joint spaces increased while the superior and posterior joint spaces reduced in temporomandibular disorders patients. CONCLUSION: There were significant differences between the patients with and without temporomandibular joint disorders in terms of mandibular fossa positions and height as well as condylar positions and inclinations in horizontal and vertical planes together with reduced condylar height and reduced posterior and superior joint spaces in the temporomandibular disorders patients. CLINICAL RELEVANCE: The temporomandibular disorder is a multifactorial disorder in which one of these factors is the dimensional and positional characteristics of the temporomandibular joints; including or excluding this factor requires a comprehensive three-dimensional investigation of patients with TMD compared to the normal group under the condition that the facial pattern is average as a confounding factor.


Assuntos
Transtornos da Articulação Temporomandibular , Articulação Temporomandibular , Adulto , Humanos , Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Côndilo Mandibular/diagnóstico por imagem , Face , Tomografia Computadorizada de Feixe Cônico
4.
J Contemp Dent Pract ; 23(11): 1091-1099, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37073931

RESUMO

AIM: This study aimed to evaluate the impact of using a magnifying dental loupe on enamel surface roughness during adhesive resin removal by different burs. MATERIALS AND METHODS: Ninety-six extracted premolar teeth were randomly divided according to the bur used with or without the aid of a magnifying loupe into four equal groups (N = 24): group I: naked eye tungsten carbide burs (NTC); group II: magnifying loupe tungsten carbide burs (MTC); group III: naked eye white stones (NWS); and group IV: magnifying loupe white stones (MWS). The initial surface roughness (Ra) T0 was evaluated using a profilometer, and the scanning electronic microscopy (SEM) technique. The metal brackets were bonded and debonded after 24 hours with debonding plier. After adhesive removal, Ra was evaluated again (T1) also the time spent on adhesive removal was recorded in seconds. The samples were finally polished by Sof-Lex discs and Sof-Lex spirals, and the third Ra evaluation was performed (T2). RESULTS: The results of two-way mixed analysis of variance (ANOVA) showed that all burs increased surface roughness at T1 as compared to T0 (p < 0.001) with the highest Ra values shown in group III followed by group IV, group I, and group II. After polishing, no significant difference was noted in Ra values in group I and group II at T0 vs T2 (p = 1.000), while it was significant in group III and group IV (p < 0.001). Regarding the time required for adhesive removal, the shortest time was in group IV followed by groups III, II, and I, respectively. CONCLUSION: The use of a magnifying loupe affects the quality of the clean-up procedure by reducing the enamel surface roughness and the time spent on adhesive removal. CLINICAL SIGNIFICANCE: Using a magnifying loupe was helpful during orthodontic debonding and adhesive removal.


Assuntos
Cimentos Dentários , Braquetes Ortodônticos , Descolagem Dentária , Esmalte Dentário , Microscopia Eletrônica de Varredura , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...